Features AW00118501000
102 Basler racer Camera Link
Enabling a Test Image Using Direct Register Access
To enable a test image via direct register access:
Set the value of the Test Image Selector register to Test Image 1, 2, 3, 4, or 5 as desired.
To disable test images:
Set the value of the Test image Selector Register to Off.
For more information about direct register access, see Section 3.2 on page 16.
8.10.1 Test Images in Detail
Test Image 1 - Fixed Horizontal Gray Gradient (8 bit)
The 8 bit fixed horizontal gray gradient test image is best suited for use when the camera is set for
monochrome 8 bit output. The test image consists of fixed horizontal gray gradients ranging from 0
to 255.
The mathematical expression for this test image is:
Gray Value = [column number] MOD 256
Test Image 2 - Moving Diagonal Gray Gradient (8 bit)
The 8 bit moving diagonal gray gradient test image is similar to test image 1, but it is not stationary.
The image moves by one pixel from right to left whenever a new line acquisition is initiated. The test
pattern uses a counter that increments by one for each new line acquisition.
The mathematical expression for this test image is:
Gray Value = [column number + counter] MOD 256