Configuring the Camera
BASLER A600
f 4-29
DRAFT
Register Name: Image Position
Offset from Base Address: 0x008
Field Name: Bit Description
Left 0 ... 15 Sets the left (starting) column of pixels for the area of interest (see Sec-
tion 3.6).
Default = 0 on all A600f cameras
Top 16 ... 31 Sets the top row of pixels for the area of interest (see Section 3.6).
Default = 0 on all A600f cameras
Register Name: Image Size
Offset from Base Address: 0x00C
Field Bit Description
Width 0 ... 15 Sets the width in columns for the area of interest (see Section 3.6).
Default = 656 on all A600f cameras
Height
16 ... 31 Sets the height in rows for the area of interest (see Section 3.6).
Default = 491 on the A601f and A602f
Default = 490 on the A601fc and A602fc
Register Name: Color Coding ID
Offset from Base Address: 0x010
Field Bit Description
Coding ID 0 ... 7 Sets the color coding. Valid color codings for Format 7 Mode 0 are
listed in the Color Coding Inquiry register (see the next register de-
scription).
Default = ID 0 on the A601f and A602f
Default = ID 2 on the A601fc and A602fc
--- 8 ... 31 Reserved